Add Proxmox inventory scripts and n8n sync workflow
- proxmox-inventory.sh: text inventory (RAM/CPU/Swap/Disk/IP/Gateway/Subnetz) - proxmox-inventory-json.sh: JSON variant with n8n webhook push, --vmids filter, --dry-run - n8n workflow: automated fact-sync between Proxmox and Outline docs, auto-creates pages for new VMIDs, ntfy summary notification - credentials (Outline/NTFY bearer tokens) intentionally excluded, see README
This commit is contained in:
@@ -0,0 +1,179 @@
|
||||
#!/usr/bin/env bash
|
||||
#
|
||||
# proxmox-inventory.sh
|
||||
#
|
||||
# Liest alle LXC-Container und VMs auf diesem Proxmox-Host aus und gibt
|
||||
# eine strukturierte Übersicht aus (VMID, Name, Status, Ressourcen, Netzwerk
|
||||
# inkl. Subnetzmaske und Gateway).
|
||||
#
|
||||
# Ausführen als root auf dem Proxmox-Host:
|
||||
# chmod +x proxmox-inventory.sh
|
||||
# ./proxmox-inventory.sh
|
||||
#
|
||||
# Die Ausgabe kannst du 1:1 kopieren und zurückgeben, um die Outline-Doku
|
||||
# aktualisieren zu lassen. Optional: Ausgabe in Datei umleiten:
|
||||
# ./proxmox-inventory.sh > inventory.txt
|
||||
#
|
||||
set -euo pipefail
|
||||
separator() { printf '%s\n' "----------------------------------------------------------------------"; }
|
||||
|
||||
# Wandelt eine CIDR-Prefixlänge (z. B. 24) in eine Subnetzmaske (255.255.255.0) um.
|
||||
cidr_to_netmask() {
|
||||
local cidr="$1"
|
||||
if ! [[ "$cidr" =~ ^[0-9]+$ ]] || [ "$cidr" -lt 0 ] || [ "$cidr" -gt 32 ]; then
|
||||
echo "-"
|
||||
return
|
||||
fi
|
||||
local mask=0
|
||||
if [ "$cidr" -gt 0 ]; then
|
||||
mask=$(( 0xffffffff ^ ((1 << (32 - cidr)) - 1) ))
|
||||
else
|
||||
mask=0
|
||||
fi
|
||||
printf "%d.%d.%d.%d\n" \
|
||||
"$(( (mask >> 24) & 255 ))" \
|
||||
"$(( (mask >> 16) & 255 ))" \
|
||||
"$(( (mask >> 8) & 255 ))" \
|
||||
"$(( mask & 255 ))"
|
||||
}
|
||||
|
||||
echo "########################################"
|
||||
echo "# Proxmox Inventar - $(hostname) - $(date '+%Y-%m-%d %H:%M:%S')"
|
||||
echo "########################################"
|
||||
echo
|
||||
# ---------------------------------------------------------------------------
|
||||
# LXC Container
|
||||
# ---------------------------------------------------------------------------
|
||||
echo "=========================================="
|
||||
echo " LXC CONTAINER"
|
||||
echo "=========================================="
|
||||
echo
|
||||
|
||||
for VMID in $(pct list | awk 'NR>1 {print $1}'); do
|
||||
separator
|
||||
echo "VMID: $VMID"
|
||||
pct list | awk -v id="$VMID" '$1==id {print "Status: " $2; print "Name (pct list): " $3}'
|
||||
|
||||
CONFIG=$(pct config "$VMID" 2>/dev/null || true)
|
||||
HOSTNAME=$(echo "$CONFIG" | grep -E '^hostname:' | cut -d' ' -f2- || echo "-")
|
||||
CORES=$(echo "$CONFIG" | grep -E '^cores:' | cut -d' ' -f2- || echo "-")
|
||||
MEMORY=$(echo "$CONFIG" | grep -E '^memory:' | cut -d' ' -f2- || echo "-")
|
||||
SWAP=$(echo "$CONFIG" | grep -E '^swap:' | cut -d' ' -f2- || echo "-")
|
||||
ROOTFS=$(echo "$CONFIG" | grep -E '^rootfs:' | cut -d' ' -f2- || echo "-")
|
||||
echo "Hostname (config): $HOSTNAME"
|
||||
echo "Cores: $CORES"
|
||||
echo "Memory (MB): $MEMORY"
|
||||
echo "Swap (MB): $SWAP"
|
||||
echo "Rootfs/Storage: $ROOTFS"
|
||||
|
||||
echo "Netzwerk-Konfiguration:"
|
||||
echo "$CONFIG" | grep -E '^net[0-9]+:' | while read -r LINE; do
|
||||
echo " $LINE"
|
||||
done
|
||||
|
||||
# Gateway und CIDR-Prefix aus der net0-Zeile der Config extrahieren (statische Konfiguration)
|
||||
NET0_LINE=$(echo "$CONFIG" | grep -E '^net0:' || true)
|
||||
CFG_GW=$(echo "$NET0_LINE" | grep -oP 'gw=\K[0-9.]+' || echo "")
|
||||
CFG_CIDR=$(echo "$NET0_LINE" | grep -oP 'ip=[0-9.]+/\K[0-9]+' || echo "")
|
||||
|
||||
# Tatsächlich zugewiesene IP + Prefix (falls Container läuft und Tools installiert sind)
|
||||
LIVE_GW=""
|
||||
LIVE_CIDR=""
|
||||
if pct status "$VMID" 2>/dev/null | grep -q running; then
|
||||
IP=$(pct exec "$VMID" -- ip -4 -o addr show scope global 2>/dev/null | awk '{print $4}' | paste -sd ', ' || echo "n/a")
|
||||
echo "Live-IP(s): $IP"
|
||||
LIVE_CIDR=$(pct exec "$VMID" -- ip -4 -o addr show scope global 2>/dev/null | head -1 | awk '{print $4}' | cut -d/ -f2 || echo "")
|
||||
LIVE_GW=$(pct exec "$VMID" -- ip -4 route show default 2>/dev/null | awk '{print $3}' | head -1 || echo "")
|
||||
else
|
||||
echo "Live-IP(s): (Container gestoppt)"
|
||||
fi
|
||||
|
||||
# Gateway: bevorzugt live ermittelt, sonst aus Config
|
||||
GW="${LIVE_GW:-${CFG_GW:-"-"}}"
|
||||
[ -z "$GW" ] && GW="-"
|
||||
echo "Gateway: $GW"
|
||||
|
||||
# Subnetzmaske: bevorzugt live ermittelter Prefix, sonst Config-Prefix
|
||||
CIDR="${LIVE_CIDR:-${CFG_CIDR:-""}}"
|
||||
if [ -n "$CIDR" ]; then
|
||||
NETMASK=$(cidr_to_netmask "$CIDR")
|
||||
echo "Subnetzmaske: $NETMASK (/$CIDR)"
|
||||
else
|
||||
echo "Subnetzmaske: -"
|
||||
fi
|
||||
|
||||
echo
|
||||
done
|
||||
|
||||
echo
|
||||
echo "=========================================="
|
||||
echo " VIRTUELLE MASCHINEN (QEMU/KVM)"
|
||||
echo "=========================================="
|
||||
echo
|
||||
|
||||
for VMID in $(qm list | awk 'NR>1 {print $1}'); do
|
||||
separator
|
||||
echo "VMID: $VMID"
|
||||
qm list | awk -v id="$VMID" '$1==id {print "Name (qm list): " $2; print "Status: " $3}'
|
||||
|
||||
CONFIG=$(qm config "$VMID" 2>/dev/null || true)
|
||||
CORES=$(echo "$CONFIG" | grep -E '^cores:' | cut -d' ' -f2- || echo "-")
|
||||
SOCKETS=$(echo "$CONFIG"| grep -E '^sockets:'| cut -d' ' -f2- || echo "-")
|
||||
MEMORY=$(echo "$CONFIG" | grep -E '^memory:' | cut -d' ' -f2- || echo "-")
|
||||
echo "Cores: $CORES"
|
||||
echo "Sockets: $SOCKETS"
|
||||
echo "Memory (MB): $MEMORY"
|
||||
echo "Disks:"
|
||||
echo "$CONFIG" | grep -E '^(scsi|sata|virtio|ide)[0-9]+:' | while read -r LINE; do
|
||||
echo " $LINE"
|
||||
done
|
||||
echo "Netzwerk-Konfiguration:"
|
||||
echo "$CONFIG" | grep -E '^net[0-9]+:' | while read -r LINE; do
|
||||
echo " $LINE"
|
||||
done
|
||||
|
||||
# Cloud-Init-Netzwerkdaten (falls vorhanden): ipconfig0: ip=X.X.X.X/24,gw=Y.Y.Y.Y
|
||||
IPCONFIG_LINE=$(echo "$CONFIG" | grep -E '^ipconfig0:' || true)
|
||||
CFG_GW=$(echo "$IPCONFIG_LINE" | grep -oP 'gw=\K[0-9.]+' || echo "")
|
||||
CFG_CIDR=$(echo "$IPCONFIG_LINE" | grep -oP 'ip=[0-9.]+/\K[0-9]+' || echo "")
|
||||
|
||||
LIVE_CIDR=""
|
||||
# QEMU-Guest-Agent IP/Prefix, falls installiert & VM läuft
|
||||
if qm status "$VMID" 2>/dev/null | grep -q running; then
|
||||
AGENT_JSON=$(qm guest cmd "$VMID" network-get-interfaces 2>/dev/null || echo "")
|
||||
IP=$(echo "$AGENT_JSON" \
|
||||
| grep -o '"ip-address":"[^"]*"' \
|
||||
| grep -v '127.0.0.1' \
|
||||
| cut -d'"' -f4 \
|
||||
| paste -sd ', ' || echo "")
|
||||
if [ -n "$IP" ]; then
|
||||
echo "Live-IP(s) via Guest-Agent: $IP"
|
||||
# Prefix der ersten nicht-lokalen Adresse ermitteln
|
||||
LIVE_CIDR=$(echo "$AGENT_JSON" | grep -oP '"prefix":\K[0-9]+' | head -1 || echo "")
|
||||
else
|
||||
echo "Live-IP(s) via Guest-Agent: n/a (kein Guest-Agent?)"
|
||||
fi
|
||||
else
|
||||
echo "Live-IP(s): (VM gestoppt)"
|
||||
fi
|
||||
|
||||
# Gateway: nur über Cloud-Init-Config ermittelbar (Guest-Agent liefert kein Gateway)
|
||||
GW="${CFG_GW:-"-"}"
|
||||
[ -z "$GW" ] && GW="-"
|
||||
echo "Gateway: $GW"
|
||||
|
||||
CIDR="${LIVE_CIDR:-${CFG_CIDR:-""}}"
|
||||
if [ -n "$CIDR" ]; then
|
||||
NETMASK=$(cidr_to_netmask "$CIDR")
|
||||
echo "Subnetzmaske: $NETMASK (/$CIDR)"
|
||||
else
|
||||
echo "Subnetzmaske: - (nicht ermittelbar ohne Cloud-Init-Config oder Guest-Agent-Prefix)"
|
||||
fi
|
||||
|
||||
echo
|
||||
done
|
||||
|
||||
echo
|
||||
echo "########################################"
|
||||
echo "# Ende der Ausgabe"
|
||||
echo "########################################"
|
||||
Reference in New Issue